– 9820MT
IP9820MT provides remote manual control of the critical devices by clicking on a few buttons on the smart phone or computer webpage. Stop the problem device by cutting off the power to a specific outlet. By cycling the power off and restarting the device remotely, you save time and money by eliminating the need to send technicians to the root cause of the problem. Managers can monitor the total power usage information of PDU from the remote end through the Internet to fully understand the power consumption of all the devices. Set up overload event alerts and notify managers via Email and TRAP, allowing managers to respond to crises in the shortest possible time to minimize disasters. Provide central management software, which can manage a large number of PDUs' power, temperature and humidity information. The database stores the power consumption information of the power strip and provides the history curve chart for the manager's reference.
– Features
• Support HTTP, HTTPS/SSL, TCP/IP, PPPOE, DHCP, DDNS, SNMP V1/2/3, SMTP, NTP, TLS.
• Support Cloud Connect : AWS IOT, GOOGLE Cloud IoT, Microsoft AZURE IOT.
• Support Telnet/SSH.
All the event will be wite on website and send to syslog host server. |
User-definable power status on/off/last time | ||
In M2M mode, if you control IPPower-A, the other IPPower-B will do the same job. It is easy to monitor the remote sites |
Remote Control If enable CNT function, please download Andriod and ios APP and Nod-red software package to control and monitor |
||
HTTP API Command your IPPower through a friendly web interface, via a curl, from a command line, or from your own application via an HTTP get post API(CGI). | MQTT API Command your IPPower through MQTT bridge of a topic, via a publish and subscribe. | ||
Ammeter Measure each power consumption to balancing circuits, preventing overloads and checking power failures. | Voltmeter Measure power voltage preventing overloads and checking power failures. | ||
PING Ping function provides 2 IP with with AND OR logic combination. When the specified IP does not respond to PING, IPPower will perform a user-defined power action. The action can be select outlet on/off/power-cycle, shutdown on LAN/wake on LAN and email notification. | Schedule Task Scheduler allows you to schedule and run actions at pre-defined time table. There are 30 time table which are selected from web calendar of everyday,week or once. When the time up IPPower perform a user-defined power action. The action can be select outlet on/off/power-cycle,shutdown on LAN/wake on LAN and email notification. | ||
VPN client mode IPPower can connect with a VPN router. It can be controlled and monitored at the same VPN |
Remote Control If enable SMTP function, If the status changed,IPPower will send notifications by email If enable POP3 function, IPPower can be controlled from email |
||
HTTP and HTTPS web server To get HTTPS connection you must upload a security certificate authority *.ca file and Privatekey *.pem file.\A You can also disable HTTP connection and use HTTPS only |
Equipped with two Ethernet ports, IPPower9820MT can be accessed on two separate networks or VLANs. Auto failover to a 2nd Ethernet-connection in the event of network interruption,ensuring 100% iPDU uptime reporting. | ||
– Specification
Dimensions | 450 x 170 x 45mm( L / W / H ) |
Input |
100~240VAC IEC C20 socket |
Output |
NEMA5 or IEC C13 socket x 8 Max current per outlet 10A Max current total 8 outlets 20A 110V / 15A 220V |
Interface |
8 LED indicator lights Reset Breaker - Fuse protection button DI sensor, can trigger an event of user-defined condition IR Sensor, online power control Restart/Reset button DC 1A 12V Output LCD Panel showing IP,each outlet current and temperature, power in voltage |
Operating temperature | 0~50°C |
Network | RJ-45 10/100Mb Ethernet port x 2 Host Port Lan Port |
USB |
USB 2.0 Port x 2 4G telecom dongle expansion power bank UPS |