IP POWER9828-P 2xOutlet | Aviosys a.s.
  • 2 ports individual power controller
  • Active Surge Filter design
  • Total Meter & Voltage & Thermometer
  • 2 Latching Relay design ( green power )
  • 2 buttons control
  • HTTPS, SNMP V1,2,3, Web API , MQTT , SSL
  • Auto Ping, Scheduler, SYSLOG , WOL & SOL
  • 100-240VAC, 15A/100VAC or 10A/240VAC
  • Smallest solution : 35mm high only
  • Option model : EAPOL(IEEE802.1x)
  • 2 outlets available : S-IEC or T-NEMA




    – 9828-P

    New profession style of dynamic color display GUI & Icon for easy using and save time. Remote control of 2 power outputs through the network for on/off/restart action 2-way sockets provides independent power control.
    Super slim/thin size metal enclosure design with 3.5 cm in height for easy install in any limited room space or narrow area

    – Features

    • Support HTTP, HTTPS/SSL, TCP/IP, PPPOE, DHCP, DDNS, SNMP v3, SMTP, NTP, TLS.
    • Support Cloud Connect : AWS IOT, GOOGLE Cloud IoT, Microsoft AZURE IOT.
    • Support Telnet/SSH.
    HTTP API Command your IPPower through a friendly web interface, via a curl, from a command line, or from your own application via an HTTP get post API(CGI).
    MQTT API Command your IPPower through MQTT bridge of a topic, via a publish and subscribe.
    Wake ON LAN IPPower allows you to remotely wake up the network devices from shutdown via the Wake on LAN (WOL) service. You can enable IPPower to the WOL service and wake them up via the MAC address list. Before applying the WOL service, make sure the target device supports WOL.
    Shutdown on LAN Since improper shutdowns may result in file system errors, IPPower provide a keep resident software on PC. IPPower allows you to remotely shutdown the network devices from pc on runing via the shutdown on LAN (SOL) service. You can enable IPPower to the SOL service and shutdown them via software and after delay timeout then turn off power.
    PING Ping function provides 2 IP with with AND OR logic combination. When the specified IP does not respond to PING, IPPower will perform a user-defined power action. The action can be select outlet on/off/power-cycle, shutdown on LAN/wake on LAN and email notification.
    Schedule Task Scheduler allows you to schedule and run actions at pre-defined time table. There are 30 time table which are selected from web calendar of everyday,week or once. When the time up IPPower perform a user-defined power action. The action can be select outlet on/off/power-cycle,shutdown on LAN/wake on LAN and email notification.
    Measure total IP9828-P current
    ippower support modbusTCP client,
    combine with SCADA tool for sysem
    integration
    All the event will be wite on website
    and send to syslog host server.
    User-definable power status on/off/last time
    In M2M mode, if you control IPPower-A,
    the other IPPower-B will do the same job.
    It is easy to monitor the remote sites
    Remote Control
    If enable CNT function, please download
    Andriod and ios APP and Nod-red software package
    to control and monitor
    VPN client mode
    IPPower can connect with a VPN router.
    It can be controlled and monitored at the same VPN
    Remote Control
    If enable SMTP function, If the status changed,IPPower will send notifications by email
    If enable POP3 function, IPPower can be controlled from email

    – Specification

    Dimensions 195 x 100 x 35mm( L / W / H )
    ( Width included two mounting ear kits of boths sides - 2.5mm x 2 )
    Power input 100~240VAC
    Maximum current per outlet 10A
    Maximum current total 2 outlets 15A 110V
    10A 220V
    Relay Type Magnetic Latching Relay
    Interface LED indicator lights
    HW Reset button
    Two push buttons
    Operating temperature -10°C~ 60°C( 14°F~ 140°F )
    Network RJ-45 10/100Mb Ethernet Port x 2
    Host Port
    Lan Port

    – Download