IP POWER9858 4xOutlet | Aviosys a.s.
  • 4x C13/NEMA5 outlet,10A
  • 100~240VAC C14 in,max 15A
  • (LxWxH) 195x116x45 mm
  • 1x Ethernet RJ45
  • Surge suppressor circuit
  • Option Model wireless
  • Option Model EAPOL(IEEE802.1x)
  • VPN Client




    – 9858MT

    IP9858MT provides remote manual control of the critical devices by clicking on a few buttons on the smart phone or computer webpage. Stop the problem device by cutting off the power to a specific outlet. By cycling the power off and restarting the device remotely, you save time and money by eliminating the need to send technicians to the root cause of the problem. Managers can monitor the total power usage information of PDU from the remote end through the Internet to fully understand the power consumption of all the devices. Set up overload event alerts and notify managers via Email and TRAP, allowing managers to respond to crises in the shortest possible time to minimize disasters. Provide central management software, which can manage a large number of PDUs' power, temperature and humidity information. The database stores the power consumption information of the power strip and provides the history curve chart for the manager's reference.

    – Features

    • Support HTTP, HTTPS/SSL, TCP/IP, PPPOE, DHCP, DDNS, SNMP v3, SMTP, NTP, TLS.
    • Support Cloud Connect : AWS IOT, GOOGLE Cloud IoT, Microsoft AZURE IOT.
    • Support Telnet/SSH.
    HTTP API Command your IPPower through a friendly web interface, via a curl, from a command line, or from your own application via an HTTP get post API(CGI).
    MQTT API Command your IPPower through MQTT bridge of a topic, via a publish and subscribe.
    Wake ON LAN IPPower allows you to remotely wake up the network devices from shutdown via the Wake on LAN (WOL) service. you can enable IPPower to the WOL service and wake them up via the MAC address or the connection list. Before applying the WOL service, make sure the target device supports WOL.
    Shutdown on LAN Since improper shutdowns may result in file system errors, IPPower provide a keep resident software on PC. IPPower allows you to remotely shutdown the network devices from pc on runing via the shutdown on LAN (SOL) service. You can enable IPPower to the SOL service and shutdown them via software and after delay timeout then turn off power.
    PING Ping function provides 2 IP with with AND OR logic combination. When the specified IP does not respond to PING, IPPower will perform a user-defined power action. The action can be select outlet on/off/power-cycle, shutdown on LAN/wake on LAN and email notification.
    Schedule Task Scheduler allows you to schedule and run actions at pre-defined time table. There are 30 time table which are selected from web calendar of everyday,week or once. When the time up IPPower perform a user-defined power action. The action can be select outlet on/off/power-cycle,shutdown on LAN/wake on LAN and email notification.
    If enable rotation,each outlet will
    power cycle in sequece and repaeat at
    dedacated time.
    It can be operating on website directly
    or by scheduler
    ippower support modbusTCP client,
    combine with SCADA tool for sysem
    integration
    All the event will be wite on website
    and send to syslog host server.
    User-definable power status on/off/last time
    In M2M mode, if you control IPPower-A,
    the other IPPower-B will do the same job.
    It is easy to monitor the remote sites
    Remote Control
    If enable CNT function, please download
    Andriod and ios APP and Nod-red software package
    to control and monitor
    VPN client mode
    IPPower can connect with a VPN router.
    It can be controlled and monitored at the same VPN
    Remote Control
    If enable SMTP function, If the status changed,IPPower will send notifications by email
    If enable POP3 function, IPPower can be controlled from email

    – Specification

    Dimensions 195 x 116 x 45mm( L / W / H )
    Power input 100~240VAC
    Maximum current per outlet 10A
    Maximum current total 4 outlets 15A 110V
    10A 220V
    Interface 4 LED indicator lights
    HW Reset button
    Operating temperature 0~50°C
    Network RJ-45 10/100Mb Ethernet port